Part Number
Definition:
A MANUALLY OR POWER OPERATED VALVE HAVING THREE OR MORE PORTS. THE DIRECTION OF THE FLOW THROUGH THE VARIOUS PORTS IS CONTROLLED BY EITHER ONE OR MORE RECIPROCATING SLIDE(S) OR SPOOL(S) WITH RECESS AREAS WHICH MATE WITH PORTS IN AN INTEGRAL OR REPLACEABLE PORTED SLEEVE, OR ONE OR MORE POPPET(S). IT IS DESIGNED TO CHANGE THE DIRECTION OF FLUID FLOW FROM ONE VALVE PORT TO ANOTHER. AN OFF (NO FLOW) POSITION IS NOT A FLOW PATTERN. THE VALVE IS DESIGNED TO ACTUATE VARIOUS COMPONENTS OF A FLUID SYSTEM. A POWER OPERATED VALVE MAY HAVE A MANUAL OVERRIDE. FOR ITEMS WHICH STOP, START, OR CHANGE THE FLOW OF FLUID, SEE: VALVE, SOLENOID. EXCLUDES VALVE, PLUG. SEE ALSO SERVOVALVE, HYDRAULIC; BODY SECTION, WORKING, LINEAR DIRECTIONAL CONTROL VALVE; AND VALVE ASSEMBLY.
CAGE Information
Code | Company |
---|---|
4M588 | BARBEE VALVE & SUPPLY INC DBA BARBEE |
Federal Supply Class
Title
VALVES, NONPOWERED
Inclusions:
INCLUDES AUTOMATIC NONPOWERED VALVES; GATE, GLOBE, ANGLE, CHECK, AND RELIEF VALVES; COCKS.
Exclusions:
EXCLUDES FIRE HYDRANTS (FSC 4210); SPRINKLER HEADS (FSC 4210); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES |
CRWH | MAXIMUM OPERATING TEMP AND MEDIA FOR WHICH DESIGNED | 200.0 DEG FAHRENHEIT OIL, HYDRAULIC |
AQLR | VALVE OPERATION METHOD | AUTOMATIC |
THSD | THREAD SERIES DESIGNATOR | NPT |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | PILOT OPERATED 2-WAY CARTRIDGE VALVE, NORMALLY OPEN |
CQRG | BODY MATERIAL | STEEL CORROSION RESISTING |
AWLS | CONNECTION TYPE | THREADED EXTERNAL PIPE |
AGAV | END ITEM IDENTIFICATION | TEST STAND |
ADQZ | END CONNECTION QUANTITY | 3 |
AAJD | THREAD CLASS | 2A |
CQCJ | MAXIMUM OPERATING PRESSURE AND MEDIA FOR WHICH DESIGNED | 5000.0 POUNDS PER SQUARE INCH OIL, HYDRAULIC |
CYGY | FLOW PATTERN QUANTITY | 2 |
FEAT | SPECIAL FEATURES | THIS CARTRIDGE VALVE IS FURNISHED IN (STANDARD) ALUMINUM HOUSING WITH 1/4 NPT CONNECTIONS TO PORTS 1 AND 2; PILOT CONNECTION 1/8 NPT. HOUSING HAS 2 MOUNTING HOLES OF 3/4-16 UNF. IF PILOT PRESSURES FALLS BELOW MINIMUM PRESSURE VALVE ACTS AS A RELIEF VALVE. DETERMINE MINIMUM PRESSURE BY MULTIPLYING MAXIMUM POSSIBLE SYSTEM PRESSURE BY 11, THEN DEVIDE TOTAL BY 26. WHEN PILOT PRESSURE FALLS BELOW THIS NUMBER VALVE WILL FUNCTION AS A PILOT OPERATED RELIEF VALVE. 26:1 PILOT RATIO |
CMLP | THREAD QUANTITY PER INCH | 27 |
AJMU | POPPET QUANTITY | 1 |
ADSY | VALVE DISCHARGE FLOW RATE | 5.0 GALLONS PER MINUTE |